Why a Power Capacitor is needed
Conservation of Energy due to LT Shunt Capacitors is an established fact. Needless to say that these Capacitors have contributed significantly in Electrical Installations by way of reduction in KVA demand for specific KW Loads, thereby saving on electricity Bills. Higher Capacity utilisation of Transformers, connecting cables and switchgears are direct saving for given specific load. These capacitors are also useful in system voltage stabilisation and distribution.
SARDA Power Capacitors are manufactured in controlled atmosphere and with modern technology to improve Power factor of Electrical Installation of all kinds of industries and in agriculture pumpsets. The Capacitors are made of Heavy edge zinc alloy metallised PP film and dry construction.
ADVANTAGE OF USING POWER CAPACITORS:
To increase the efficiency of the electrical system, power factor is improved by providing power capacitors in the electrical system. Some of the major advantages of using power Capacitor are :-
- Reduction in Electricity bill.
- Reduction of power losses.
- Improvement in Voltage regulation.
- Meet statutory requirement & avoid penalty.
TYPES: STANDARD HEAVY DUTY DOUBLE DIELECTRIC ALUMINIUM CYLINDRICAL
| STANDARD TYPE |
| These Capacitors are light weight and compact in size have been designed keeping in view, the normal duty cycle present in various utilities. These Capacitors are used for almost constant loads having negligible variations. |
|
| HEAVY DUTY TYPE |
|
| These Capacitors have been designed to suit fluctuating load conditions and withstand over-voltage and over-currents within permissible limits. These Capacitors are stronger than standard type to withstand required dielectric stress which varies non-linearly. |
|
| DOUBLE DIELECTRIC TYPE |
|
| Aiming at replacing the conventional mixed dielectric and film-foil oil type capacitors, our double dielectric type is designed to suit continuous operation for heavy duty application particularly where presence of harmonics plays a prominent role. These Capacitors are mechanically robust and electrically stable to withstand combined effects of thermal and electrical stresses prevalent in major industries. |
|
| ALUMINIUM CYLINDRICAL TYPE |
|
| |
Top ^ |
|
| SPECIAL
FEATURES
|
|
| ISI marked
|
|
| Approved by various
State Electricity Boards.
|
|
| Self Healing MPP Film
with Heavy Edge Metallization.
|
|
| Manufactured with latest
state of art technology
|
|
| High Insulation Properties
|
|
| Low Losses and longer
life
|
|
| Dry Construction
|
|
| Burst-proof modules.
|
|
| Compact Size
|
|
| Better power handling
capacity
|
|
| With/without inductor
coil
|
|
| Non-modular / modular
construction
|
|
| Multiple modules per
rated output
|
|
| Quality system ISO:9001-2000
|
|
|
ELECTRICAL
PARAMETERS: |
| Sl.No. |
Electrical Characteristics |
Standard |
Heavy Duty |
Double Dielectric |
Aliminium Cylindrical |
1 |
Rated Voltage (VAC) |
250 / 415 / 440 |
415 / 440 |
415 / 440 |
400/440 |
2 |
Max Over Voltage
(Max 8Hrs per day) |
1.1 Rated |
1.2 Rated |
1.3 Rated Volt |
1.1 Rated Volt |
3 |
Max. Over Current * (Short Duration) |
1.3 Rated |
1.4 Rated |
1.6 Rated |
1.3 Rated |
4 |
Rated Frequency (Hz) |
50 |
50 |
50 |
50 |
5 |
Capacitance Tolerance |
-5% to + 10% |
-5% to + 10% |
-5% to + 10% |
-5% to + 10% |
6 |
Temperature Category |
-5 C to 50 C |
-5 C to 50 C |
-5 C to 50 C |
-5 C to 50 C |
7* |
Losses |
5 x 10 - 4 |
5 x 10 - 4 |
5 x 10 - 4 |
5 x 10 - 4 |
8 |
Max. Ambient Temp. |
50 C |
50 C |
50 C |
50 C |
9 |
Max. Avg. Temp. Over 24 Hrs |
40 C |
40 C |
40 C |
40 C |
10 |
Max. Avg. Temp. Over 1 Year |
30 C |
30 C |
30 C |
30 C |
11 |
Internal Connection |
Single Phase
Three Phase Delta |
Three Phase Delta |
Three Phase Delta |
Single Phase
ThreePhase Delta |
12 |
Application |
Indoor |
Indoor |
Indoor |
Indoor |
13 |
Insulation Level (KVAC) |
3/- |
3/- |
3/- |
3/- |
14 |
Discharge Device |
External |
External |
External |
External |
15 |
Ref. Standard IS: |
13340-1993-1334-1992 |
16 |
Ref. Standard IEC |
60831-1(2002) |
| * Altered Voltage and Rated Frequency |
* After Stabilization |
Top ^
POWER CAPACITOR
BOX DIMENSIONS (in mm)
Rated KVAr |
STANDARD TYPE |
HEAVY DUTY |
DOUBLE DIELECTRIC |
Length |
Width |
Height |
Length |
Width |
Height |
Length |
Width |
Height |
1 |
120 |
45 |
130 |
150 |
60 |
190 |
170 |
60 |
245 |
2 |
145 |
50 |
170 |
185 |
65 |
190 |
180 |
65 |
265 |
3 |
170 |
65 |
210 |
185 |
65 |
190 |
190 |
65 |
295 |
4 |
170 |
65 |
210 |
185 |
65 |
315 |
215 |
75 |
295 |
5 |
170 |
65 |
220 |
185 |
65 |
315 |
215 |
75 |
420 |
6 |
170 |
65 |
220 |
185 |
65 |
315 |
215 |
75 |
420 |
7 |
210 |
70 |
240 |
210 |
75 |
315 |
215 |
75 |
420 |
8 |
210 |
70 |
240 |
210 |
75 |
315 |
215 |
150 |
420 |
9 |
210 |
70 |
240 |
210 |
75 |
315 |
215 |
150 |
420 |
10 |
210 |
70 |
242 |
220 |
80 |
425 |
270 |
200 |
465 |
12 |
250 |
90 |
375 |
220 |
80 |
425 |
270 |
200 |
465 |
12.5 |
250 |
90 |
375 |
250 |
98 |
425 |
270 |
200 |
465 |
15 |
250 |
90 |
375 |
250 |
90 |
425 |
270 |
270 |
465 |
20 |
220 |
160 |
375 |
270 |
160 |
425 |
375 |
375 |
485 |
25 |
220 |
160 |
375 |
220 |
160 |
425 |
375 |
375 |
485 |
Top ^
Selection
of Power Capacitors
With the advancement of Technology in the Capacitor field,
new designs to suit common industrial and agricultural requirements
including that of Rolling Mills, Induction Furnaces, Thyristor controlled Drivers
both AC & DC) Heavy presses, Rectifiers, Advance welding system and other such loads, have been developed.
Top ^
|