1. |
Operating Temperature Range |
-40° C To +85° C |
3. |
Surge Voltage
(Times the rated voltage) |
Up to 100 WV = 1.25 XWV
150 To 350 WV = 1.2 XWV
350 To 450 WV = 1.14 XWV
500WV = 1.1 XWV |
4. |
Capacitance Range & Tolerance
at 100Hz & 25°C |
Range: 100 Mfd to 1,00,000 Mfd
Tolerance: -10% To +30% |
5. |
Leakage Current (µA Max)
(Apply rated voltage for 5
minutes before test) |
I= 0.003 CV
I= Leakage Current (µA)
C= Rated Capacitance (Mfd)
V= Rated Voltage (V) |
6. |
Dissipation Factor (% Max at 100Hz & 25°C) |
Rated Voltage |
16 |
25 |
40 |
50 |
63 |
100 |
200 |
250 |
350 |
400 |
450 |
500 |
Tanð |
24 |
22 |
20 |
20 |
20 |
20 |
15 |
15 |
15 |
15 |
15 |
15 |
When the capacitance exceed 1000Mfd, the specification of Tanð is increased by 2% for every addition of 1000 Mfd. |
|
7. |
Life Test at 85°C & at Rated Voltage |
Test Hours-2000 Hours
Capacitance change -within ± 20% of the initial value
Tanð/ Dissipation Factor- Less Than 120% of column 6
Leakage Current -Less Than the value given in column 5 |
8. |
Other Tests |
As per IS-4317-1983 (Category)
2B |